{"product_id":"victron-gx-tank-140-bpp920140100","title":"Victron - GX Tank 140 [BPP920140100]","description":"\u003cp style=\"margin: 0cm 0cm 7.5pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;\"\u003e\u003cspan lang=\"EN-GB\" style=\"\" arial color:\u003eThe GX Tank 140 takes readings from up to four tank level sensors. It is an accessory for our range of GX system monitoring products, of which the \u003ca href=\"https:\/\/www.victronenergy.com\/panel-systems-remote-monitoring\/cerbo-gx\" target=\"_blank\" style=\"\"\u003eCerbo GX \u003c\/a\u003eis the most commonly used model.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"margin: 0cm 0cm 7.5pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;\"\u003e\u003cspan lang=\"EN-GB\" style=\"\" arial color:\u003eTank levels can be read-out locally in the system, see screenshot, as well remotely through our \u003ca href=\"https:\/\/vrm.victronenergy.com\/\" target=\"_blank\"\u003eVRM Portal\u003c\/a\u003e.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"margin: 0cm 0cm 7.5pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;\"\u003e\u003cspan lang=\"EN-GB\" style=\"\" arial color:\u003eThe GX Tank 140 is compatible with current senders (4 to 20 mA) as well as voltage senders (0 to 10 V). The connection to the GX Device is via USB, which is also how the GX Tank is powered: no additional power wires required.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"margin: 0cm 0cm 7.5pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;\"\u003e\u003cspan lang=\"EN-GB\" style=\"\" arial color:\u003eTank sender wiring is kept as simple as possible: two of the four inputs provide a 24 V power supply, to power the sender. The other two channels do require an external power supply, and there is a power in terminal together with fused outputs to facilitate that. \u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"margin: 0cm 0cm 7.5pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;\"\u003eUpper and lower limits are configurable, to allow using senders that provide only part of the scale, for example 0 to 5 V.\u003c\/p\u003e\u003cp style=\"margin: 0cm 0cm 7.5pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;\"\u003e\u003cspan lang=\"EN-GB\" style=\"\" arial color:\u003eTo provide a stable reading, the readings are averaged damping. The damping can be configured between 1 and 60 seconds.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"margin: 0cm 0cm 7.5pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;\"\u003e\u003cspan lang=\"EN-GB\" style=\"\" arial color:\u003eFaulty sensors and wiring issues are detected: an alarm will be raised when values are out of range.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp style=\"margin: 0cm 0cm 7.5pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;\"\u003e\u003cspan lang=\"EN-GB\" style=\"\" arial color:\u003eFor marine applications, the \u003cspan style=\"background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;\"\u003eGX Device can transmit these tank levels on the NMEA 2000 network to be picked up by other displays such as an MFD.\u003c\/span\u003e\u003cspan style=\"font-size: 10.5pt;\"\u003e\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":63317671477617,"sku":"BPP920140100","price":98.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0998\/8214\/0017\/files\/BPP920140100_GX_20Tank_20140_20_front.png?v=1774127299","url":"https:\/\/www.sequencesolar.com\/products\/victron-gx-tank-140-bpp920140100","provider":"Sequence Solar","version":"1.0","type":"link"}